Case Studies
HomeCase StudiesApplication Case | HT8700 Uses High-Precision Data to Analyze Biosphere–Atmosphere Ammonia Exchange in a Pine Forest Region
Paper source:Melman, E.A., et al. (2026). On the efficiency of biosphere–atmosphere ammonia exchange processes over a Scots pine forest and its link to ecosystem activity.Agricultural and Forest Meteorology, 389, 111358.
Background
Ammonia (NH ₃) is the most important alkaline gas in the atmosphere and a key carrier of reactive nitrogen (Nr). It is both an “indicator” of agricultural non-point source pollution and, through dry deposition, profoundly affects biodiversity, soil acidification, and nitrogen saturation processes in forest ecosystems. To assess the ecological impacts of ammonia, a core question must be answered: How efficient are the ammonia exchange processes between forests and the atmosphere?
However, long-term, high-frequency observations of ammonia fluxes have long been an internationally recognized technical challenge:
Ammonia is highly adsorptive: in closed-path analyzers, ammonia molecules adhere to the inner walls of inlet tubing and filters, causing signal lag and attenuation.
Turbulence in forest canopies is complex: the traditional aerodynamic gradient method (AGM) has large errors within the roughness sublayer and relies on the questionable assumption that “ammonia and heat transport are similar.”
The eddy covariance (EC) method is a more direct approach, but for a long time there has been a lack of open-path high-speed ammonia analyzers suitable for EC.
A research team from the Dutch National Institute for Public Health and the Environment (RIVM), Wageningen University & Research (WUR), and the Netherlands Organisation for Applied Scientific Research (TNO) jointly published a study inAgricultural and Forest Meteorology. Relying on the ICOS (Integrated Carbon Observation System) NL-Loo site, the team used the Healthy Photon HT8700E Open-Path NH ₃ Analyzer (HT8700E is the EU version of HT8700) to achieve the world’s first continuous year-round, high-frequency ammonia flux observations over a temperate pine forest, systematically analyzing the efficiency of different exchange processes and their links to ecosystem productivity.

Observation System Setup
Observation site
The Loobos forest in the Netherlands (52°09′N, 5°44′E) is a Scots pine (Pinus sylvestris) forest planted in 1911, with a canopy height of about 21 m. It is adjacent to an intensive livestock farming area (Foodvalley) and has high atmospheric ammonia exposure, making it an ideal natural laboratory for studying biosphere–atmosphere ammonia exchange.

Original Fig. 1: (a) Site location and distribution of surrounding farmland (potential ammonia source areas); (b) satellite imagery around the observation tower and flux footprint climatology (gray box indicates target area); (c) topographic elevation map around the site.
Core instrument: HT8700 Open-Path NH ₃ Analyzer
The HT8700 Open-Path NH ₃ Analyzer uses quantum cascade laser absorption spectroscopy (QCLAS). Its high-frequency concentration analysis characteristics make it highly suitable for micrometeorological eddy covariance measurements. Combined with a flux observation system, it can accurately quantify the net ammonia exchange flux between different ecosystems and the atmosphere.
Open-path design: sampled air does not pass through any inlet tubing, significantly reducing adsorption and response lag caused by tubing and enabling high-frequency real-time sampling and a high concentration detection limit.
Mid-infrared quantum cascade laser: selects the core region of a strong NH ₃ absorption band and reduces spectral interference with major atmospheric constituents such as H ₂ O through line selection, ensuring high selectivity and sensitivity.
Unattended continuous monitoring: quick installation design and low power consumption facilitate deployment and maintenance at remote field sites or on small vehicles.
Observation tower configuration
The observation tower is 36 m tall, with a top mast extending to 38.2 m:

Original Fig. 2: (a) Side view—multi-level instrumentation on the 36 m observation tower (T2), including sonic anemometers, HT8700E (HT), miniDOAS (mD, optical path connecting T1 and T2), radiation, leaf wetness and phenology cameras, etc.; (b) top view—relative positions of HT8700E and the sonic anemometer (horizontal separation about 2.7 m) and the approximately 11 m oblique measurement optical path of miniDOAS.
Field calibration and data processing
In response to the instrument temperature sensitivity found in previous studies, the research team used synchronous miniDOAS observations to perform field calibration of the HT8700E: linear/multiple regression correction models were established based on 30-minute mean concentrations (a cubic polynomial temperature correction was introduced during the 2024 deployment period). Results showed that data without field calibration would lead to an overestimation of fluxes by about 22%, highlighting the necessity of field calibration.
The 10 Hz raw data were processed with EddyPro 7.0.4 into 30-minute fluxes, including empirical correction for high-frequency spectral loss and WPL density correction improved for ammonia absorption lines. After strict quality screening (signal strength OSS >20%, adequate turbulence, target footprint area, etc.), high-quality flux data coverage reached 43%. Combined with XGBoost machine-learning gap filling, a complete annual flux series was constructed. The observation period was from August 2023 to September 2024, and the HT8700E uptime during the deployment period was 76%.
Monitoring Results
Overall characteristics of ammonia concentration and flux
Median ammonia concentration was 6.1 μg m ⁻ ³ and mean was 7.9 μg m ⁻ ³, with peaks in March and August (fertilization season); the highest half-hour concentration reached 171.2 μg m ⁻³.
Ammonia flux ranged from -1.84 to +0.34 μg m ⁻² s⁻ ¹; 87% of the time it showed deposition (forest uptake of ammonia), with a mean flux of -0.13 μg m ⁻² s⁻¹.
After gap filling, annual dry deposition was as high as 32.0 ± 4.5 kg N ha ⁻¹ yr⁻ ¹, about 3–4 times the historical observations at a neighboring site 10 km away, and one of the highest forest ammonia deposition loads reported in the Netherlands to date.
Original Fig. 5: (a) Ammonia concentration measured by miniDOAS; (b) ammonia flux measured by HT8700E; (c) annual time series of turbulent velocity; (d) synchronous changes in cumulative ammonia deposition and cumulative GPP and LAI.
Comparison of exchange efficiencies among six process categories
Using screening conditions such as leaf wetness, radiation, and humidity, the study divided the data into six exchange scenarios and compared them with the turbulence-permitted maximum theoretical flux (Fmax) to quantify the exchange efficiency of each process:

Key finding: Due to the high water solubility of ammonia, exchange with wet leaf surfaces is the most efficient ammonia sink. At night under wet-leaf conditions, the observed flux was almost equal to the theoretical upper limit of turbulent transport, with no sign of saturation. Although daytime turbulence was strongest, the stomatal compensation point and stomatal resistance significantly suppressed exchange. During the observation period, the canopy was wet 38% of the time, which is an important reason for the extremely high deposition load at this site.

Original Fig. 7: Observed ammonia flux (gray) and turbulence-permitted maximum flux Fmax (pink) versus ammonia concentration under six screening scenarios. In the wet-leaf nighttime scenario (e), the observed flux was almost equal to the theoretical upper limit, indicating the highest exchange efficiency.
Diurnal and seasonal variation patterns
Diurnal variation: In most months, deposition was strongest at night (high humidity and low temperature enhance ammonia solubility), and weakest during the day or even showed emission (emissions after stomatal opening offset deposition).
Seasonal variation: In summer months, gross primary productivity (GPP) was significantly positively correlated with monthly-scale ammonia exchange velocity (R² = 0.61; daytime-only data reached 0.74), while no such relationship existed in winter. The study proposed a hypothesis: in early spring, nitrogen transport from storage tissues to leaf buds (remobilization) increases emission potential and suppresses deposition; as the growing season progresses, photosynthesis-driven nitrogen assimilation strengthens, and the forest’s capacity to absorb ammonia increases accordingly.

Original Fig. 8: Relationship between effective exchange velocity and cumulative GPP. There was no significant correlation at the daily scale (R² < 0.01), while a significant positive correlation appeared at the monthly scale in summer (R² = 0.61; daytime-only data reached 0.74), with no such relationship in winter (blue dots).
Model testing and site comparison
Although the official Dutch deposition model DEPAC could reproduce the diurnal variation pattern, it underestimated the summer deposition trend, with annual cumulative flux underestimated by about 45%, suggesting that the model needs a seasonal parameterization scheme using GPP as a proxy.
Comparison with the neighboring Speulderbos Douglas fir forest (annual deposition 8.5–11.8 kg N ha ⁻¹ yr⁻ ¹) found that although the two sites are only 10 km apart and both are high-ammonia-exposure coniferous forests, their flux magnitudes differed by 3–4 times. This arises from differences in tree species nitrogen metabolism strategies and ecosystem nitrogen availability—the Scots pine forest is more “nitrogen-limited” with low emission potential and almost “takes up all” ammonia; while the Douglas fir forest is nitrogen-rich with a high compensation point, forming a “push-back” effect on ammonia deposition.

Original Fig. 11: Probability density distributions of ammonia concentration, exchange velocity, and ammonia flux at Loobos (gray) and Speulderbos (blue). Speulderbos fluxes were concentrated near zero (more emission events and a strong “push-back” effect), while Loobos was dominated by significant deposition flux.
Outlook: Broad prospects for open-path ammonia flux observations
Using a full year of high-temporal-resolution ammonia flux data, this study demonstrates that the open-path laser ammonia analyzer plus the eddy covariance method has become a powerful tool for analyzing biosphere–atmosphere ammonia exchange processes. The HT8700E withstood year-round field tests in the humid, rainy, high-ammonia-load forest environment of the Netherlands, providing a replicable technical paradigm for similar ecological observations.
In the future, this observation system will play a greater role in the following directions:
Model improvement: provide data support for introducing ecological activity parameterization such as GPP into deposition models such as DEPAC, improving the accuracy of regional nitrogen deposition assessments.
Multi-site networking: conduct comparative observations in forests with different tree species and different nitrogen deposition gradients to clarify the regulatory mechanisms of vegetation nitrogen metabolism on ammonia exchange.
“Flux + physiology” joint observations: combine soil and plant tissue C/N content measurements to understand the ecological effects of ammonia deposition from the “perspective of forest vegetation.”
Broader application scenarios: from forests to farmland, grassland, and cities, open-path ammonia flux observations can provide direct observational basis for validation of agricultural ammonia emission inventories, nitrogen cycle research, and evaluation of ammonia reduction policies.
The Healthy Photon HT8700 Open-Path NH ₃ Analyzer—with high-speed, sampling-line-free open-path measurement—helps scientists analyze the invisible ammonia exchange between forests and the atmosphere, providing a solid data cornerstone for nitrogen cycle research and ecological environmental protection.
(+86) 400-961-6990
info@healthyphoton.com
Room 305, Building 1, Zhongchuang Science Park, Jinyuan Road, Panhuo Street, Yinzhou District, Ningbo, China
Speak with our experts to find the right sensing solution for your application.
Innovation for Green Life
Precision sensing solutions for environmental monitoring, scientific research, and industrial applications.? HealthyPhoton Technology Co., Ltd. All Rights Reserved.Privacy PolicyTechnical Support:Chemical Instrument Networksitemap.xml