Choose Language

Case Studies

Case Studies

HomeCase StudiesApplication Case | TNO Collaboration Results: HT8700 Achieves High-Resolution Identification of Mobile Sources and Improves Emission Inventory Verification Accuracy

Application Case | TNO Collaboration Results: HT8700 Achieves High-Resolution Identification of Mobile Sources and Improves Emission Inventory Verification Accuracy

Carbon Asset Management System2026-8- 28

Lead: Ammonia is an important precursor to atmospheric fine particulate matter, but its emission sources are spatially dispersed and released instantaneously, making it difficult for traditional fixed or offline sampling methods to capture effectively. Recently, our long-term partner—the team from the Netherlands Organisation for Applied Scientific Research (TNO)—published a mobile monitoring study on EGUsphere. Equipped with the HT8700 Open-Path NH₃ Analyzer, they successfully captured and distinguished ammonia emission sources such as livestock housing, fertilized fields, and traffic exhaust around the Veluwe Natura 2000 protected area, preliminarily quantified the emission intensities of various source types, and provided an efficient technical solution for dynamic inventory verification and evaluation of emission reduction measures.

image.png


Method Core: Open-Path Design Eliminates Tubing Adsorption Effects

The strong adsorptivity of ammonia causes traditional closed-path analysis systems to generally suffer from tubing retention and response delay, making them unable to meet the rapid-response requirements of mobile monitoring. The HT8700E Open-Path NH₃ Analyzer integrated in this study directly measures atmospheric ammonia, avoids sampling tubing, and increases the concentration output rate to 1–10 Hz. This enables the mobile platform to capture source plumes less than 100 m wide at normal driving speeds of 50–80 km/h and to record the spatial variation of ammonia concentration in real time.
On this basis, the research team established a plume identification and background subtraction algorithm and simultaneously equipped a closed-path multi-gas analyzer (TILDAS) to obtain co-emitted tracers such as methane and carbon monoxide. By calculating the integrated enhancement ratio of plumes (ΣNH₃:ΣCH₄) as a source fingerprint, the method can preliminarily distinguish the three main source types—livestock housing, fertilized fields, and traffic exhaust—without complex dispersion models.

image.png

Figure caption: Mobile monitoring vehicle equipped with the HT8700E Open-Path NH₃ Analyzer (front left) and the TILDAS closed-path multi-component analyzer.


Field Results: ΣNH₃:ΣCH₄ Ratio Effectively Distinguishes Emission Sources

During a half-day mobile monitoring campaign of about 160 km, 49 fixed sources and approximately 630 traffic plumes were identified. The integrated enhancement ratios of different sources showed systematic differences:
● Livestock housing: median 0.04 for cattle farms, 0.26 for pig farms, and 0.42 for poultry farms, consistent with the high methane emission characteristics of enteric fermentation in ruminants;
● Freshly fertilized fields: median ratio 2.1, but with large variability, consistent with the pattern of ammonia pulse release after fertilization;
● Traffic exhaust: the ratio of long-residence plumes can reach 4.59, significantly higher than that of agricultural sources.

image.png

Figure caption: Box plot of ΣNH₃:ΣCH₄ for plumes from livestock housing, fertilized fields, traffic, and industrial sources. The ratio differences are significant and can be used for rapid source-type identification.

Comparison with the Dutch national emission inventory (KRD) shows that the ratio of measured to inventory values for ammonia emissions averaged 2.2, with a weaker correlation than methane, and emission activities at some sites were not covered by the inventory. This indicates that inventories based on annual average factors are difficult to reflect the dynamic changes of actual emissions, and that mobile field measurements are of great value for verifying inventories and capturing emission pulses caused by management activities.
For traffic sources, the carbon balance method was used to estimate NH₃ emission factors at different vehicle speeds. The overall geometric mean was 0.18 g kg⁻¹ fuel, but the emission factor in the high-speed segment (>80 km/h) rose to 0.28 g kg⁻¹, exceeding the 0.14 g kg⁻¹ implied by the Dutch 2023 inventory. This result suggests that existing inventories may underestimate ammonia emissions in highway scenarios.

image.png

Figure caption: Scatter plot of NH₃ emission factors based on ~630 traffic plumes; emission factors clearly increase in the high-speed segment.


Key Advantages of HT8700

The open-path design of HT8700E is the key support that moved this mobile monitoring from theory to practical application:
● Fast response: high-frequency data output ensures the ability to capture narrow plumes;
● No tubing adsorption: direct measurement of open atmospheric ammonia, with a true and sharp signal and no memory effect;
● In-situ measurement: no sampling pump is required, making it easier to integrate on mobile platforms and suitable for large-area mobile monitoring.
These features directly ensure the quality of high-time-resolution synchronized ammonia and methane data, enabling effective implementation of the ΣNH₃:ΣCH₄ ratio analysis method. If a traditional closed-path system were used, the lag and smoothing of the ammonia signal would severely weaken the ratio-based discrimination capability.


Outlook: Advancing Toward Routine Mobile Monitoring

A single mobile monitoring campaign verified the feasibility of the method, but ammonia emissions are significantly affected by temperature, wind speed, and management activities. The research team noted that future work should conduct repeated observations across multiple seasons and meteorological conditions and integrate license plate recognition and high-precision meteorological modules to reduce inversion uncertainty. As open-path instruments such as HT8700E become further lightweight and more widespread, building low-cost, grid-based mobile ammonia monitoring systems will become possible, providing efficient technical means for dynamic verification of regional emission inventories, area-source tracking, and assessment of emission reduction effects.
Conclusion: The application of the open-path ammonia analyzer has achieved a leap in ammonia emission observation from static inventory estimation to dynamic spatial tracking, with clear significance for improving the precision of ammonia emission control in livestock farming and transportation.

Contact Healthyphoton
  • (+86) 400-961-6990

  • info@healthyphoton.com

  • Room 305, Building 1, Zhongchuang Science Park, Jinyuan Road, Panhuo Street, Yinzhou District, Ningbo, China

Full Name*
Phone Number*
Email Address*
Please Enter Full Name!
Please Enter A Valid Mobile Phone Number!
Please Enter A Valid Email Address!
Submission Successful
Submission Failed

Speak with our experts to find the right sensing solution for your application.

Innovation for Green Life

Precision sensing solutions for environmental monitoring, scientific research, and industrial applications.

Scan The Code To Follow Us

Scan The Code To Follow Us

? HealthyPhoton Technology Co., Ltd. All Rights Reserved.Privacy PolicyTechnical Support:Chemical Instrument Networksitemap.xml

(+86) 400-961-6990

info@healthyphoton.com

Scan the code to add WeChat