Accurately and continuously obtaining ecosystem-scale methane exchange fluxes is an important basis for understanding the global methane cycle and assessing ecosystem greenhouse gas budgets. In recent years, eddy covariance (EC) technology, with its advantages of continuous observation, large-scale representativeness, and non-disturbing measurement, has become an important technical means for studying methane fluxes in wetlands, croplands, forests, and other ecosystems.
However, for open-path methane EC observations, how to further improve long-term measurement stability and reduce uncertainties introduced by environmental factors remains a continuing concern in this field.

Recently, a study jointly published by Healthy Photon innpj Climate and Atmospheric Science, titled“Towards correction free open-path eddy covariance flux measurements for methane”proposed a new open-path methane flux measurement method, providing a new technical pathway to address this issue.
This study focuses on environmental effects and post-processing correction issues in open-path methane measurements. By optimizing the instrument measurement mechanism, it reduces the method’s dependence on correction processes and achieves more direct and stable methane EC flux observations.
I. Correction challenges in open-path methane EC measurements
Because the measurement path is directly exposed to the environment, changes in temperature, water vapor, and air density affect the gas concentration signal output by conventional open-path methane gas analyzers. In conventional open-path EC data processing, density correction and spectral correction are usually required to correct for the effects of environmental changes.
These methods have supported a large amount of long-term ecological observation work. However, under low-background flux conditions, large correction terms may increase data processing complexity and introduce additional uncertainty.
Therefore, how to reduce environmental effects from the measurement process itself, rather than relying on large post-processing corrections, has become an important direction for the development of open-path methane EC technology.
II. From “post-processing correction” to “measurement process optimization”
To address the above issues, we proposed a new measurement method. The core idea of this method is:
By optimizing the measurement mechanism, methane concentration changes are affected as little as possible by environmental factors at the acquisition stage.
Based on theHT8600P Open-Path CH ₄/H₂ O Analyzer (hereinafter referred to as “8600P”), the study adopts mid-infrared laser spectroscopy technology and proposes a pseudo-dry mixing ratio (χ ₚ) method.
Simply put, conventional methods usually:
Measure methane concentration changes → calculate raw fluxes → correct based on factors such as temperature and water vapor
The new method attempts to:
Simultaneously measure CH ₄ and H₂ O along the same optical path → perform point-by-point compensation to achieve density-to-mixing-ratio conversion → reduce correction requirements
This approach changes the conventional open-path EC way of “relying on corrections to compensate for errors,” making measurement results closer to directly obtaining the true gas exchange signal.
III. Experimental validation: reducing environmental effects and improving flux reliability
The research team systematically validated the HT8600P and the χ ₚ method through zero-flux experiments and actual environmental observations.
In zero methane flux background experiments, the results showed:
The net correction required by the HT8600P was about 1/10 that of conventional commercial solutions (instrument + method);

By reducing density and spectral effects at the signal level, the χ ₚ method significantly reduced the overestimation of random error estimates caused by environmental disturbances such as temperature and water vapor—the “phantom error”—making the estimated random error level (about 0.057 mg·m ⁻²·h⁻ ¹) consistent with independent empirical validation results (about 0.063 mg·m ⁻²·h⁻¹);

In addition, in urban methane emission observation experiments, the HT8600P and a commercial open-path methane analysis system achieved highly consistent flux results, verifying the applicability of the method under actual environmental conditions.
The study shows that by reducing measurement interference caused by environmental factors, this method can improve the stability of open-path methane flux observations and provide a more reliable data foundation for long-term continuous observations.
IV. A new pathway for next-generation methane flux observations
For long-term ecosystem observations, instrument performance is reflected not only in single-measurement accuracy but also in stability and data consistency during multi-year operation.
This study optimized open-path methane EC technology at both the monitoring hardware and computational methodology levels, providing a new technical option for future methane emission observations in wetlands, croplands, forests, and at regional scales.
TheHT8600P Open-Path CH ₄/H₂ O Analyzerused in this study was developed by Healthy Photon. In the future, in response to the high-precision monitoring needs for key greenhouse gases such as methane and nitrous oxide, the relevant technologies will further serve ecosystem greenhouse gas exchange research and the construction of long-term observation networks.