HomeCase StudiesApplication Case: HT8700 Open-Path Analyzer for NH3 Emission Measurement at a Multi-Animal Shed Farm of Shanxi University

Application Case: HT8700 Open-Path Analyzer for NH3 Emission Measurement at a Multi-Animal Shed Farm of Shanxi University

Ecological environment monitoring2026-8- 3

Project Location:

A farm in Beitousi Village, Yuci District, Jinzhong City, Shanxi Province, where pigs, cows, and sheep are simultaneously raised.

Project Background:

With the development of society and the expansion of the livestock industry, the impact of agricultural NH3emissions on environmental air quality has been increasing. These emissions have a significant presence in the natural environment and can promote the formation of secondary aerosols and haze, even indirectly affecting the production of O3in the atmosphere.

Project Objectives:

To understand the emission and dispersion patterns ofNH3in livestock sheds, to comprehend the influence ofNH3on the formation of secondary aerosols, and to employ models for accurate and comprehensive assessment of atmosphericNH3.


Analysis Methods:

This project utilized an open-path laserNH3analyzer (HT8700) for online measurement ofNH3concentrations in the livestock farm. The analyzer was mounted on a mobile platform (Figure 2.3a) and included the Healthy Photon HT8700 Atmospheric Ammonia Laser Open-Path Analyzer, data acquisition module, GPS module, ultrasonic three-dimensional wind speed module, and real-time data processing module (Figure 2.3b).



The project conducted a comparative experiment on measurement accuracy between the nano-reagent spectrophotometric method (HJ533-2009) and the open-path laserNH3analyzer.



Conclusion:

A comparison between the results of NH3measurements obtained by the national standard method (nano-reagent spectrophotometric method) and the open-path laser NH3analyzer (HT8700) revealed that HT8700 produced NH3concentration values higher than those of the national standard method. However, these differences were within an acceptable range and did not hinder the use of HT8700 for measuring NH3in the livestock farm. HT8700 is an open-path, real-time measurement instrument that is convenient and flexible, making it suitable for capturing short-term fluctuations in NH3levels in the livestock farm.


Related papers: Li Ruijin, Geng Hong, and Fu Yuling from Shanxi University, "Multiple Livestock Houses in Livestock FarmsNH3Research on Emission Measurement and Its Impact on Secondary Aerosol Formation

10.27284/d.cnki.gsxiu.2021.001027

Contact Healthyphoton
  • (+86) 400-961-6990

  • info@healthyphoton.com

  • Room 305, Building 1, Zhongchuang Science Park, Jinyuan Road, Panhuo Street, Yinzhou District, Ningbo, China

Full Name*
Phone Number*
Email Address*
Please Enter Full Name!
Please Enter A Valid Mobile Phone Number!
Please Enter A Valid Email Address!
Submission Successful
Submission Failed

Speak with our experts to find the right sensing solution for your application.

Innovation for Green Life

Precision sensing solutions for environmental monitoring, scientific research, and industrial applications.

Scan The Code To Follow Us

Scan The Code To Follow Us

? HealthyPhoton Technology Co., Ltd. All Rights Reserved.Privacy PolicyTechnical Support:Chemical Instrument Networksitemap.xml

(+86) 400-961-6990

info@healthyphoton.com

Scan the code to add WeChat